Note: Refer to the appropriate installation manual for details on avoiding loss of PLC memory contents when replacing a memory backup battery. Remove the standard memory backup battery from the system after installing the auxiliary battery module. PACSystems RX7i BATTERY Slot in ACCESS battery access door Be careful not to pinch the battery cable when closing the battery compartment cover. For these CPUs, either replace the door (supplied with the IC698ACC701 replacement battery) or leave the door off. An earlier version RX7i CPU may not have a notch in its battery door. Run the battery cable through the slot on the battery door and reinstall the battery door. PACSystems RX3i The battery connector is on the CPU module. Run the battery cable into the notch at the bottom of the battery compartment and close the battery door. Series 90-70 Central Processor Unit OK ENABLE RUN Opening in bottom of CPU module Notch at base of battery compartment The battery connector is on the CPU module. The cable must be routed out the bottom of the CPU module. Series 90-30 The battery connector is on the CPU module. The cable must be routed through the slot in the bottom of the battery compartment. HIGH CAPACITY B A T T E R Y Slot in bottom of power supply The battery connector is located on the power supply module in the CPU baseplate.
#Ge fanuc versamax ic200udr005 bc install
To maximize battery life, it is recommended that you install it after power has been turned on.) 100 - 240 VAC PROGRAMMABLE CONTROLLER + PWR OK RUN BATT GE Fanuc Serie s 90 - 30 POWER SUPPLY 50/60 HZ 100VA 125VDC, 50W INPUT 24 VDC OUTPUT 0.8A MAX.

(Note that the battery will begin to drain immediately unless power is applied. Connect the cable from the battery module to the battery connector on the PLC. Securely attach the Auxiliary Battery Module to the panel mounting surface using four #8-32 x flat head machine screws. Use care to keep metal chips from falling into other equipment. With power removed from the equipment, drill four #29 (0.136 ) holes in the panel mounting surface, and tap for #8-32 threads, according to the hole pattern shown in the following figure. Battery packs that have been in storage for several years (depending on the CPU type and how critical the application is) should be discarded because these units have a finite shelf life of seven years. The last two digits represent the fiscal week of manufacture for example 11 stands for fiscal week 11. The first digit represents the year of manufacture in the 21st century such as.
#Ge fanuc versamax ic200udr005 bc code
The date code consists of three digits, such as 211. Date Code The date code is located on the product label on the front of the auxiliary battery module. Save the shipping containers and packing material in case it is necessary to transport or ship any part of the system.
#Ge fanuc versamax ic200udr005 bc serial
After unpacking the equipment, record all serial numbers.

Save the damaged shipping container for inspection by the delivery service. If any equipment is damaged, notify the delivery service immediately. Related Documents Series 90-70 Installation Manual, GFK-0262 Series 90-30 Installation Manual, GFK-0356 PACSystems RX7i Installation Manual, GFK-2223 PACSystems RX3i System Manual, GFK-2314 Date Code Pre-installation Check Carefully inspect all shipping containers for damage. The Auxiliary Battery Module replaces the standard CPU RAM backup battery in your control system.

Auxiliary Battery Module IC693ACC302 GFK-2124A for Series 90 and PACSystems April 2005 The optional IC693ACC302 Auxiliary Battery Module provides an extended memory backup time compared to that of the standard memory backup batteries for Series 90-30, Series 90-70, and PACSystems CPUs.